站内搜索
|
详细信息 Product Name: 12kv/24kv, 630A/ 1250A Medium Voltage Electrical Switchgear Model NO.: SM66 Current: AC Structure: Floorstanding Installation: Fixed Voltage Level: Medium Voltage Shell Material: Aluminum Alloy Certification: ISO9001 Trademark: powertech Transport Package: Wooden Packing Specification: IEC, GB Origin: Zhejiang, China HS Code: 8537109090 Product Description ++++GeneralSM66-40.5 unit type SF6 RMU with SF6 load switch as main switch, for whole cabinet is suitable for electric distribution automation and compact also expandable metal close switchgear. It characters in its simple structure, flexible operation, reliable interlocking and convenient installation etc., which can provide the satisfactory technical projects both for different application occasions and users. With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, SM66-40.5 unit type SF6 RMU can completely meet the requirement of continuously variable market. It can take self-produced RLS-40.5 load break switch; also according to the demand of users can be assembled with the internationally top-ranking RCB series vacuum circuit breaker with permanent magnetic mechanism made by AREVA or HD4 type SF6 circuit breaker made by AREVA or HD4 type SF6 circuit breaker made by ABB or with our VSC-40.5 type vacuum circuit breaker with permanent magnetic mechanism. Operational methods for the main switch inside ring main unit can be either manual or electric power driven. And It can meet the requirement of "Four Controls" when matched with FTU and RTU.++++Service enviromenet:a) Air temperature: Maximum temperature: +40ºC; Minimum temperature:-25ºCb) Humidity: Monthly average humidity 95%; Daily average humidity 90% .c) Altitude above sea level: Maximum installation altitude: 2000md) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.e) No frequent violent shake++++Units for all functions:1. Incoming unit with switch disconnector(Load break switch) schemas with other extra components optional2. Outgoing unit with Fuse-switch protection schemas with other extra components optional3.Incoming/outgoing circuit breaker protection schemas with other extra components optional4. MV metering schemas with other extra components optional5. Casings (Bus bar Panel) schemas with other extra components optional++++Main technical specifications:No.ItemUnitParameter1Rated voltagekV362Rated frequencyHz50/603Rated currentA163041min Power frequency withstand voltagekV805Lightning impulse withstand voltagekV1956Rated short circuit breaking current (peak)kA50/407Rated active load/close circuit breaking currentA50/408Rated transferring currentA8009Rated short circuit making current (peak)kA50/4010Rated cable(line) charging breaking currentA50 and 1011Cable charge breaking current in earthing faultA5012Rated withstand current (peak)kA50/4013Short time withstand current (2s)kA1614Mechanism lifetimes2000Note: For short circuit breaking and peak current is based on Fuse plus combination.
|